Novice here, so please bear with me.I purchased a DSC Power832 (PC5010) with expander module, wirelessreciever (for those places impossible to get wire to) and LED keypad.My dealer was most helpful in getting me setup and teaching me how toprogram it myself.(I'm an electronics/computer guy, so having this neato electronic thingand not having any knowledge of the 'workings' was unnacceptable).There's two things on my mind.a. About once every three months, the system reports a tamper to themonitoring station, which phones me, I tell them to ignore it, etc.The panel, as best I can determine after punching in all the keys, nevertells me what caused the tamper, and indeed, never shows any sort faultas having happened at all.This leads me to.b. In article, petem wrote: hope it helped.Yup, I think so.If I understand, the panel is programmed either to 'speak' out its modem (tothe central monitoring station) or to speak out its serial port to a localPC, but not both.I have downloaded a copy of the DLS3 software, that explains how to programthe panel to speak out the serial port, but not documnet how to put it back!Perhaps my installer can help.
Or maybe I can figure it out from thedownloaded info.Thanks again.Alan-Alan Rothenbush The Spartans do not ask the number of theAcademic Computing Services enemy, only where they are.Simon Fraser University Burnaby, B.C., Canada Agix of SpartaDorian Kruse01.07.04 21:15. Alan Rothenbush wrote in message news.Alan, The PC5401 is not what you need. The PC5401 is for RS232conection to other systems and controls.
The DLS software conects tothe panel thru a modem. You will need to get the DLS software and theproper Modem (which by the way is extremly slow, since the last time Idownloaded a panel) and downkoad the panel make any changes and uploadit back to the panel. The tamper could be from the wireless devicescover or a number of other things, I don't think the download softwareis going to be of any help but it sounds like you might have fun withit.
It is pretty cool software and the PC 832 is by far the best panelon the market. If I can be of more assitance let me know.Interested01.07.04 22:12. Alan Rothenbush wrote in message news. b. What do I have to buy to allow me to examine the programming and the 'reports' on a computer. I think I need a PCLINK cable, which certainly looks like something I can wire up in a minute, and I guess I need the DLS software, which I can purchase from a few sites.
But do I need anything else? I suspect I need a PC5401 module, as I cannot think of where else to connect a PCLINK cable to.A PCLINK should do what you need. There should be a 4-pin header onthe panel labeled something like 'PC Link', usually it is slightly upand to the left of center of the board.You can make one in a few minutes- the pinout is available. I seem toremember a resistor being the only thing close to being an 'odd' item.Then you also need DLS.Shouldn't need a 5401 unless you're doing some interesting stuff.Interested.Frank Olson01.07.04 22:16.
'Alan Rothenbush' wrote in messagenews:[email protected]. Novice here, so please bear with me. I purchased a DSC Power832 (PC5010) with expander module, wireless reciever (for those places impossible to get wire to) and LED keypad. My dealer was most helpful in getting me setup and teaching me how to program it myself. (I'm an electronics/computer guy, so having this neato electronic thing and not having any knowledge of the 'workings' was unnacceptable). There's two things on my mind. a.
About once every three months, the system reports a tamper to the monitoring station, which phones me, I tell them to ignore it, etc.Disable 'general system tamper' reporting (location 338). This usually 'cures'the problem with version 2.0 boards.Someone's already provided you the answer for the rest.:-))Robert L Bass02.07.04 4:27. And downkoad the panel make any changes and upload it back to the panel.For the sake of clarity (and to avoid a nasty surprise:)), you download.to.the panel and upload.from. it. If you get the terminology wrong it's easyto wipe out your programming.Alarm and Home Automation System FAQRegards,RobertBass Home Electronics2291 Pine View CircleSarasota Florida 34231877-722-8900 Sales & Tech Support941-925-9747 Fax941-232-0791 WirelessNextel Private ID - 161.21755.1Robert L. Bass02.07.04 4:30. A PCLINK should do what you need.
There should be a 4-pin header on the panel labeled something like 'PC Link', usually it is slightly up and to the left of center of the board. You can make one in a few minutes- the pinout is available. I seem to remember a resistor being the only thing close to being an 'odd' item. Then you also need DLS. Shouldn't need a 5401 unless you're doing some interesting stuff.That is correct. The PC-LINK9 and the software are cheap.
I carry both inmy online store.Alarm and Home Automation System FAQRegards,RobertBass Home Electronics2291 Pine View CircleSarasota Florida 34231877-722-8900 Sales & Tech Support941-925-9747 Fax941-232-0791 WirelessNextel Private ID - 161.21755.1Mark Leuck02.07.04 7:38. Many thanks to all who've helped. I think I've got it now.I am VERY embarrassed to say that while I have been an EE for some30 years now, I entirely missed the 4 pin PCLINK connector onthe panel! Darkish closet, failing eyesight, evil shadow are myexcuses. I have one last question that I'm not clear on. In article, Mark Leuck wrote: Disable 'general system tamper' reporting (location 338). This usually 'cures' the problem with version 2.0 boards.
But it doesn't cure the actual tamper, I'd find out what that is firstAgreed.That's one of the reasons why I want to get this PCLINK/DLS thingworking, to have a look ata. The current programming (both for archive purposes and to understandhow the zillion settings might interact), andb. The event buffer, to see if there's something in there that doesn'tshow up with all my button pressesThat's also why I'm interested in a PC5401, to log all events and maybemake some sense from those.(It is not, as my wife insists, just another toy. It is a seriousand necessary component of our overall security system. She shouldbelieve me, and not her lying eyes!)Alan-Alan Rothenbush The Spartans do not ask the number of theAcademic Computing Services enemy, only where they are.Simon Fraser University Burnaby, B.C., Canada Agix of SpartaRH.Campbell02.07.04 12:36. Sir, there is nothing special you need to do.
By going into section 499 inthe sequence you describe, the panel will communicate via the PC link cable.When you exit, it will always use the modem for outgoing communications withthe central station. There is nothing special you need to do.However, in your software, you must default the laptop / software to theoption of using the PC Link cable instead of it looking for a modemconnection for the panel to go into PC Link communications mode. In otherwords, you must force it to communicate through the PC Link connection.RHC'Alan Rothenbush' wrote in messagenews:[email protected] 6:27.
On Thu, 8 Jul 2004 19:37:46 -0400, 'petem' wrote:if someone want to download i will keep it on the server!!! Ok,I realize this is a very old thread. However, I'll give it a try at least.I'm looking for sw to program my DSC PC 5015 (Power 832) V 3.22 C. That i bought used and want to install in our house.I'm however not that excited about doing all the programming using the keypad (not realizing how hard it would be to get hold of the sw for the computer.Can anyone help me out??!As far as i understand i need DLS 2002 + intl driver pack (cannot find) + driver for the PC 5015 (cannot find)I will runt a PK5500 wired keypad so i guess these are the only drivers needed, right?Can anyone help me get these [email protected] 21:07.